Oecd Guidelines For The Testing Of Chemicals Section 2 Test No 251 Rapid Androgen Disruption Activity Reporter Radar Assay


Download Oecd Guidelines For The Testing Of Chemicals Section 2 Test No 251 Rapid Androgen Disruption Activity Reporter Radar Assay PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Oecd Guidelines For The Testing Of Chemicals Section 2 Test No 251 Rapid Androgen Disruption Activity Reporter Radar Assay book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages.

Download

OECD Guidelines for the Testing of Chemicals, Section 2 Test No. 251: Rapid Androgen Disruption Activity Reporter (RADAR) assay


OECD Guidelines for the Testing of Chemicals, Section 2 Test No. 251: Rapid Androgen Disruption Activity Reporter (RADAR) assay

Author: OECD

language: en

Publisher: OECD Publishing

Release Date: 2022-06-30


DOWNLOAD





The Rapid Androgen Disruption Activity Reporter (RADAR) Test Guideline describes an aquatic assay that utilizes transgenic Oryzias latipes (O. latipes, Japanese medaka) eleutheroembryos at day post hatch zero, in a multi-well format to detect chemicals active on the androgen axis.

Lignes directrices de l'OCDE pour les essais de produits chimiques, Section 2 Essai n°251 : Essai de détection rapide d’un rapporteur de l’activité de perturbation androgénique (RADAR)


Lignes directrices de l'OCDE pour les essais de produits chimiques, Section 2 Essai n°251 : Essai de détection rapide d’un rapporteur de l’activité de perturbation androgénique (RADAR)

Author: OECD

language: fr

Publisher: OECD Publishing

Release Date: 2022-06-30


DOWNLOAD





La présente Ligne directrice relative à l’essai RADAR (Rapid Androgen Disruption Activity Reporter) décrit un essai aquatique faisant appel à des éleuthéroembryons d’Oryzias latipes (O. latipes, médaka japonais) transgénique au jour zéro après éclosion, dans un format multipuits, afin de détecter les produits chimiques agissant sur l’axe androgénique.

OECD Guidelines for the Testing of Chemicals, Section 4 Test No. 458: Stably Transfected Human Androgen Receptor Transcriptional Activation Assay for Detection of Androgenic Agonist and Antagonist Activity of Chemicals


OECD Guidelines for the Testing of Chemicals, Section 4 Test No. 458: Stably Transfected Human Androgen Receptor Transcriptional Activation Assay for Detection of Androgenic Agonist and Antagonist Activity of Chemicals

Author: OECD

language: en

Publisher: OECD Publishing

Release Date: 2023-07-04


DOWNLOAD





This Test Guideline describes in vitro assays, which use Androgen Receptor TransActivation (ARTA) to detect Androgen Receptor Agonists and Antagonists. The ARTA assay methods are mechanistically and functionally similar test methods that provide information on the transcription and translation of a reporter gene following the binding of a chemical to the androgen receptor and subsequent transactivation.