Distributed Educated Throat Stability Bypass To Increase The Stable Airflow Range Of A Mach 2 5 Inlet With 60 Percent Internal Contraction


Download Distributed Educated Throat Stability Bypass To Increase The Stable Airflow Range Of A Mach 2 5 Inlet With 60 Percent Internal Contraction PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Distributed Educated Throat Stability Bypass To Increase The Stable Airflow Range Of A Mach 2 5 Inlet With 60 Percent Internal Contraction book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages.

Download

Distributed Educated Throat Stability Bypass to Increase the Stable Airflow Range of a Mach 2.5 Inlet with 60-percent Internal Contraction


Distributed Educated Throat Stability Bypass to Increase the Stable Airflow Range of a Mach 2.5 Inlet with 60-percent Internal Contraction

Author: Robert Joseph Shaw

language: en

Publisher:

Release Date: 1974


DOWNLOAD





The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. A distributed educated throat stability-bypass entrance configuration was tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 16.1 percent was obtained if a constant pressure was maintained in the bypass plenum. Limited unstart angle of attack data are presented.

Distributed Porous Throat Stability Bypass to Increase the Stable Airflow Range of a Mach 2.5 Inlet with 60 Percent Internal Contraction


Distributed Porous Throat Stability Bypass to Increase the Stable Airflow Range of a Mach 2.5 Inlet with 60 Percent Internal Contraction

Author: Robert Joseph Shaw

language: en

Publisher:

Release Date: 1974


DOWNLOAD





The results of an experimental investigation to increase the stable airflow operating range of a supersonic, mixed-compression inlet with 60-percent internal contraction are presented. Various distributed-porous, throat stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 25 percent was obtained with the optimum configuration if a constant pressure was maintained in the by-pass plenum. The location of the centerbody bleed region had a decided effect on the overall inlet performance. Limited unstart angle-of-attack data are presented.